BCFXP - DE-OX-ID 10-1916 AFTER 10/75

  • MSDS: BCFXP
  • Manufacturer: G C ELECTRONICS
  • Product Name: DE-OX-ID 10-1916 AFTER 10/75
  • National Stock Number: 6850-00N000631
Product Identification

Product ID:DE-OX-ID 10-1916 AFTER 10/75
MSDS Date:01/01/1985
FSC:6850
NIIN:00N000631
MSDS Number: BCFXP

Responsible Party
G C ELECTRONICS
1801 MORGAN ST
ROCKFORD, IL 61105-1209
US

Emergency Phone: 815-968-9661

Info Phone: 815-968-9661

Cage: GO905

Contractor
GC THORSEN
ROCKFORD, IL 61105 US

Telephone: 815-968-9661

Cage: 72653

Ingredients

PETROLEUM DISTILLATES (NAPHTHA OR RUBBER SOLVENT)

CAS: 8002-05-9

RTECS: SE7449000

Fraction By Weight: 65%.

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM; 8990


CHLORINATED HYDROCARBON PERCENT IS APPROXIMATE.

Fraction By Weight: 10%.

ACGIH TLV: 100 PPM (MFR)


SPECIAL LIGHT OIL PERCENT IS APPROXIMATE

Fraction By Weight: 20%.

Hazards

Effects of Overexposure:DIZZINESS, NAUSEA.

First Aid

First Aid:INHALATION:MOVE TO FRESH AIR. CALL MD. INGESTION:DO NOT
INDUCE VOMITING. CALL MD.

Fire Fighting

Flash Point:120 F CC
Extinguishing Media:C0*2, FOAM
Fire Fighting Procedures:VENTILATE AREA WELL.
Unusual Fire/Explosion Hazard:IF IGNITED, TOXIC GASES ARE EMITTED. DO
NOT STORE NEAR HEAT OR FLAME. TEMPS >120 F MAY BURST CAN.

Accidental Release

Spill Release Procedures:VENTILATE AREA WELL. WIPE UP W/ABSORBENT
MATERIAL.

Handling

Handling and Storage Precautions:DO NOT STORE NEAR HEAT OR FLAME OR
TEMPS ABOVE 120F AS CAN MAY BURST.
Other Precautions:USE W/ADEQUATE VENTILATION.

Exposure Controls

Ventilation:LOCAL EXHAUST-YES
Eye Protection:GLASSES
Supplemental Safety and Health
DATA COVERS DE-OX-ID 10-1902 (2 OZ),10-1906 (6 OZ), 10-1916 (16 OZ).
FORMULATION & TRADE NAMES CHANGED 10/75. SEE INDEX FOR DE-OX-ID
19-2,19-6,19-16 PRIOR TO 10/75.

Chemical Properties

Spec Gravity:0.877
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR-PETROLEUM DISTILLATE
Percent Volatiles by Volume:15.

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:IF IGNITED, TOXIC GASES ARE EMITTED.

Disposal

Waste Disposal Methods:MFR SUGGESTS INCINERATION OR LANDFILL IN
ACCORDANCE W/LOCAL, STATE, AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.